>>>>>> Function starting 06/17/05 00:39:58 >>>>>>

[BREAK Wakeup A]
WorkHorse Broadband ADCP Version 16.21
RD Instruments (c) 1996-2002
All Rights Reserved.
>TS050617004001
>CZ

Powering Down

>>>>>> Function starting 06/17/05 00:41:48 >>>>>>

[BREAK Wakeup A]
WorkHorse Broadband ADCP Version 16.21
RD Instruments (c) 1996-2002
All Rights Reserved.
>DEPLOY?
Deployment Commands:
RE ----------------------- Recorder ErAsE
RN ----------------------- Set Deployment Name

WD = 111 100 000 --------- Data Out (Vel,Cor,Amp; PG,St,P0; P1,P2,P3)
WF = 0704 ---------------- Blank After Transmit (cm)
WN = 030 ----------------- Number of depth cells (1-128)
WP = 00045 --------------- Pings per Ensemble (0-16384)
WS = 1600 ---------------- Depth Cell Size (cm)
WV = 175 ----------------- Mode 1 Ambiguity Vel (cm/s radial)

TE = 01:00:00.00 --------- Time per Ensemble (hrs:min:sec.sec/100)
TF = **/**/**,**:**:** --- Time of First Ping (yr/mon/day,hour:min:sec)
TP = 01:20.00 ------------ Time per Ping (min:sec.sec/100)
TS = 05/06/17,00:41:50 --- Time Set (yr/mon/day,hour:min:sec)

EA = +00000 -------------- Heading Alignment (1/100 deg)
EB = +00000 -------------- Heading Bias (1/100 deg)
ED = 00000 --------------- Transducer Depth (0 - 65535 dm)
ES = 35 ------------------ Salinity (0-40 pp thousand)
EX = 11111 --------------- Coord Transform (Xform: Type,Tilts,3 Bm,Map)
EZ = 1111101 ------------- Sensor Source (C,D,H,P,R,S,T)

CF = 11111 --------------- Flow Ctrl (EnsCyc;PngCyc;Binry;Ser;Rec)
CK ----------------------- Keep Parameters as USER Defaults
CR # --------------------- Retrieve Parameters (0 = USER, 1 = FACTORY)
CS ----------------------- Start Deployment

>SYSTEM?
System Control, Data Recovery and Testing Commands:
AC ----------------------- Output Active Fluxgate & Tilt Calibration data
AF ----------------------- Field calibrate to remove hard/soft iron error
AR ----------------------- Restore factory fluxgate calibration data
AX ----------------------- Examine compass performance
AZ ----------------------- Zero pressure reading

CB = 411 ----------------- Serial Port Control (Baud; Par; Stop)
CP # --------------------- Polled Mode (0 = NORMAL, 1 = POLLED)
CZ  ---------------------- Power Down Instrument

FC ----------------------- Clear Fault Log
FD ----------------------- Display Fault Log

OL ----------------------- Display Features List

PA ----------------------- Pre-Deployment Tests
PC1 ---------------------- Beam Continuity
PC2 ---------------------- Sensor Data
PS0 ---------------------- System Configuration
PS3 ---------------------- Transformation Matrices

RR ----------------------- Recorder Directory
RF ----------------------- Recorder Space used/free (bytes)
RY ----------------------- Upload Recorder Files to Host

>TS?
TS = 05/06/17,00:42:21 --- Time Set (yr/mon/day,hour:min:sec)
>PS0
  Instrument S/N:  5836
       Frequency:  76800 HZ
   Configuration:  4 BEAM, JANUS
     Match Layer:  10
      Beam Angle:  20 DEGREES
    Beam Pattern:  CONVEX
     Orientation:  UP
       Sensor(s):  HEADING  TILT 1  TILT 2  DEPTH  TEMPERATURE  PRESSURE
Pressure Sens Coefficients:
              c3 = +3.504519E-12
              c2 = -3.257647E-07
              c1 = +5.864309E-01
          Offset = -5.345936E+01

Temp Sens Offset:  -0.25 degrees C

    CPU Firmware:  16.21 [0]
   Boot Code Ver:  Required:  1.13   Actual:  1.13
    DEMOD #1 Ver:  ad48, Type:  1f
    DEMOD #2 Ver:  ad48, Type:  1f
    PWRTIMG  Ver:  85d3, Type:   5

Board Serial Number Data:
   A7  00 00 03 A4 9C 6C  09 DSP727-2001-06G
   2C  00 00 03 A4 83 1C  09 REC727-1004-06A
   AE  00 00 00 E6 FC 2E  09 HPI727-3007-O0A
   37  00 00 03 A4 80 75  09 TUN727-1005-06A
   6A  00 00 03 A4 3B 1D  09 CPU727-2000-00J
   CB  00 00 00 E7 10 33  09 HPA727-3009-00A
>PA

PRE-DEPLOYMENT TESTS

CPU TESTS:
  RTC......................................PASS
  RAM......................................PASS
  ROM......................................PASS
RECORDER TESTS:
  PC Card #0...............................NOT DETECTED
  PC Card #1...............................DETECTED
    Card Detect............................PASS
    Communication..........................PASS
    DOS Structure..........................PASS
    Sector Test (short)....................PASS
DSP TESTS:
  Timing RAM...............................PASS
  Demod  RAM...............................PASS
  Demod  REG...............................PASS
  FIFOs....................................PASS
SYSTEM TESTS:
  XILINX Interrupts... IRQ3  IRQ3  IRQ3 ...PASS
  Receive Loop-Back........................PASS
  Wide Bandwidth...........................PASS
  Narrow Bandwidth.........................PASS
  RSSI Filter..............................PASS
  Transmit.................................PASS
SENSOR TESTS:
  H/W Operation.........................***FAIL***
>PC2

Press any key to quit sensor display ...

Heading   Pitch    Roll   Up/Down    Attitude Temp   Ambient Temp   PRESSURE
267.16  22.32 -24.56     Up          23.29C        22.15C         1.2 kPa
>RS
RS = 000,061 ------------- REC SPACE USED (MB), FREE (MB)

>PC1


BEAM CONTINUITY TEST

When prompted to do so, vigorously rub the selected
beam's face.

If a beam does not PASS the test, send any character to
the ADCP to automatically select the next beam.

Collecting Statistical Data...
  24  23  18  22

Rub Beam 1 = PASS
Rub Beam 2 = PASS
Rub Beam 3 = PASS
Rub Beam 4 = PASS

>CZ

Powering Down

>>>>>> Function starting 06/17/05 00:47:08 >>>>>>

[BREAK Wakeup A]
WorkHorse Broadband ADCP Version 16.21
RD Instruments (c) 1996-2002
All Rights Reserved.
>CR1
[Parameters set to FACTORY defaults]
>CQ255
>CF11101
>EA0
>EB0
>ED3800
>ES35
>EX11111
>EZ1111111
>WA50
>WB1
>WD111100000
>WF704
>WN40
>WP10
>WS1200
>WV175
>TE00:30:00.00
>TP03:00.00
>CK
[Parameters saved as USER defaults]
>The command CS is not allowed in this command file.  It has been ignored.
>The following commands are generated by this program:
>CF?
CF = 11101 --------------- Flow Ctrl (EnsCyc;PngCyc;Binry;Ser;Rec)
>CF11101
>RN Dpl1_
>cs

>>>>>> Function starting 06/17/05 00:49:41 >>>>>>

>>>>>> Function starting 06/17/05 00:53:32 >>>>>>

[BREAK Wakeup A]
WorkHorse Broadband ADCP Version 16.21
RD Instruments (c) 1996-2002
All Rights Reserved.
>CR1
[Parameters set to FACTORY defaults]
>CQ255
>CF11101
>EA0
>EB0
>ED3700
>ES35
>EX11111
>EZ1111111
>WA50
>WB1
>WD111100000
>WF704
>WN40
>WP10
>WS1200
>WV175
>TE00:30:00.00
>TP03:00.00
>TF05/06/17 03:00:00
>CK
[Parameters saved as USER defaults]
>The command CS is not allowed in this command file.  It has been ignored.
>The following commands are generated by this program:
>CF?
CF = 11101 --------------- Flow Ctrl (EnsCyc;PngCyc;Binry;Ser;Rec)
>CF11101
>RN Dpl1_
>cs

>>>>>> Function starting 06/17/05 00:59:58 >>>>>>

[BREAK Wakeup A]
WorkHorse Broadband ADCP Version 16.21
RD Instruments (c) 1996-2002
All Rights Reserved.
>CR1
[Parameters set to FACTORY defaults]
>CQ255
>CF11101
>EA0
>EB0
>ED3700
>ES35
>EX11111
>EZ1111111
>WA50
>WB1
>WD111100000
>WF704
>WN40
>WP10
>WS1200
>WV175
>TE00:30:00.00
>TP03:00.00
>TF05/06/17 03:00:00
>CK
[Parameters saved as USER defaults]
>The command CS is not allowed in this command file.  It has been ignored.
>The following commands are generated by this program:
>CF?
CF = 11101 --------------- Flow Ctrl (EnsCyc;PngCyc;Binry;Ser;Rec)
>CF11101
>RN Dpl1_
>cs